Industrial dust collectors are selected around the job, not a single model name. Start with the collection point, material, available power, expected runtime, mobility and the way dust will be handled after collection. This guide helps you compare practical configurations and then open the dedicated product page for the model family that fits.
Start with your job
- Collection point: Tell us whether the collector will support a floor grinder, surface-preparation tool, shot-blasting work, post-grinding cleanup or a fixed industrial process.
- Material and workload: Describe the material, how it is generated and whether the work is intermittent or expected to run for extended periods.
- Available power: Check whether the site has single-phase 110 V or 220 V supply, or three-phase 380 V supply.
- Dust-handling workflow: Consider continuous bagging, a collection bucket or an integrated pre-separator layout before comparing individual models.
- Site constraints: Include the working area, access route, need for mobility and the equipment or process the collector will support.
Choose a model family
Single-phase bagged collectors for mid-size floor work
JF502 and JF503 are single-phase 220 V, 3.6 kW models with continuous bagging, intended for mid-size concrete floor grinders. Their key decision point is the cleaning approach: JF502 uses blowback vibration, while JF503 uses electric vibration plus blowback vibration. Open the dedicated product pages for the full model details.
Automatic-cleaning models for floor preparation
JF84 and JF85 are single-phase, continuous-bagging options with automatic cyclic reverse-air cleaning for concrete grinding and floor preparation. JF84 is listed with 220 V supply; JF85 is listed with 220 V or 110 V supply. Use the individual pages to review the configuration that matches the power available on site.
Integrated pre-separator arrangements
JF602 and JF603 combine a dust extractor and pre-separator in one frame for concrete grinding and polishing workflows. Both are listed as single-phase 220 V, 3.6 kW configurations. JF602 uses blowback/reverse-air cleaning; JF603 uses electric vibration plus blowback vibration. Confirm the collection method and required accessories for JF603 before ordering.
Compact and three-phase options
For smaller floor-preparation and post-grinding cleanup tasks, the JF92 series is listed in 110 V or 220 V single-phase versions with continuous bagging and manual reverse-air cleaning. For three-phase applications, consider the JFK5 compact family for a 30 L bucket configuration, or the JF3x heavy-duty family for longer-running, heavy-material work with a 100 L split structure.
Quick comparison
| Model family | Typical starting point | パワー | Collection and cleaning approach | エクスペリエンス |
|---|---|---|---|---|
| JF502 | Mid-size concrete floor grinding or shot blasting | Single-phase 220 V, 3.6 kW | Continuous bagging; blowback vibration | View JF502 |
| JF503 | Mid-size concrete floor grinding | Single-phase 220 V, 3.6 kW | Continuous bagging; electric vibration plus blowback vibration | View JF503 |
| JF84 / JF85 | Concrete grinding and floor preparation | Single-phase; see model page for listed voltage | Continuous bagging; automatic cyclic reverse-air cleaning | View JF84 · View JF85 |
| JF602 / JF603 | Concrete grinding and polishing with an integrated pre-separator | Single-phase 220 V, 3.6 kW | Integrated pre-separator layout; see each page for cleaning and collection details | View JF602 · View JF603 |
| JF92 series | Floor preparation and post-grinding cleanup | Single-phase 110 V or 220 V, 1.2 kW | Continuous bagging; manual reverse-air cleaning | View JF92 |
| JFK5 compact family | Compact three-phase industrial cleaning | Three-phase 380 V, 1.3 / 2.2 / 3.0 kW | 30 L collection bucket; manual blowback cleaning | View JFK5 |
| JF3x heavy-duty family | Longer-running, heavy-material industrial work | Three-phase 380 V, 3.0 / 4.0 / 5.5 / 7.5 kW | 100 L split structure; manual dust vibration | View JF3x |
How JF502 and JF503 differ
These two single-phase, 3.6 kW models share continuous bagging and are both listed for mid-size concrete floor grinders. Choose JF502 when its blowback-vibration configuration fits the job. Choose JF503 when electric vibration plus blowback vibration is the required cleaning approach. For all other differences, use the individual product pages and discuss the working setup before ordering.
Plan the right setup with us
Send your material, process or equipment, supply voltage, expected working time, working area and preferred dust-handling workflow. We can help you narrow the selection and identify the product page to review next.
Request a model recommendation · Browse all dust extractor models · Explore industrial vacuum cleaners
Frequently asked questions
What information should I provide for a recommendation?
Provide the material, collection point, process or equipment, available voltage, expected runtime, work area and how you plan to handle collected dust.
When should I start with a single-phase or three-phase model?
Start with the power available on site. This page links to single-phase and three-phase model families so you can compare the available configurations before discussing the job in detail.
When should I consider an integrated pre-separator arrangement?
Consider JF602 or JF603 when an integrated pre-separator configuration on one frame matches the concrete grinding or polishing workflow. Confirm the collection method and accessories with the team before ordering.